Data Sheet: Low Pass Filter
This Low Pass Filter has a passband from DC to its cutoff frequency (Fco) - customer defined between 550 and 1000 MHz - with an insertion loss of 0.8 dB max. (1.7 dB max. at Fco). It has a stopband from 1.1000 x Fco to at least 8000 MHz, with an attenuation of at least 60 dB.

WLJE5-___EE

550 MHz < Fco < 1000 MHz Stopband Limit 8000 MHz Slope 0.1 x Fco Attenuation 60 dB min.

Specifications

Typical Performance

5 Section Cauer Design

Cauer

Technical drawing

Typische Leistung – Wainwright Instruments
Connector Options:
  • N - Female
  • N - Male
Passband DC to MHz

choose Fco between 550 and 1000 MHz

Insertion Loss 0.8 dB max. (1.7 max. at Fco)
Return Loss 14 dB min. (VSWR 1.5:1 max.)
Stopband 8000 MHz
Stopband Attenuation 60 dB min.
Operating Temperature 5 °C to 45 °C
Power Handling max. 1 W CW into a 2:1 VSWR (See our warranty)
Dimensions (L x W x H) max. 90 x 12.7 x 21 mm (connectors may protrude)
Approx. Weight 0.09 kg
Mounting Provision 7.5 mm flanges on both ends with M3 threaded holes
Connector 1
Connector 2

Unit prices

1–4 pieces

990 €

5-9 pieces

941 €

10-24 pieces

891 €

25-49 pieces

842 €

50-99 pieces

792 €

100+ pieces

743 €

Delivery Terms

1 Delivery time: normally 4 to 6 weeks - depending on quantity ordered and on our work load.

Customer is responsible for observing all applicable export laws in regard to filter application and location of end user.

Certifications

ISO 9001
ISO 14001
Ohris
RoHs / REACH